·GGDZ series lighting saver technology
1、Regulates voltage intelligently to save electricity
2、Enhances the power factor to electricity
3、Eliminates surge and harmonic wave to save electricity

·GGDZ series lighting saver structure and work principle
    The GGDZ series lighting saver is composed by the compensation transformer, the regulating transformer, the non-contact control patent technology (or stepless voltage control technology), the sampling electric circuit, the master control electric circuit, the voltage regulate circuit, time control circuit, the protection circuit and so on. According to the lighting load characteristic and the electrical network voltage actual situation, sampling voltage separately, and regulate voltage separately of three phase.


·GGDZ series lighting saver
  1、 Regulate voltage to save electricity
  2、 Soft start preheating
  3、 Non-contact(or stepless) regulate voltage

·GGDZ series lighting saver using and shaping
  Usage place of GGDZ series lighting saver
  Municipal administration illumination - - urban road, highway, tunnel, bridge and so on;
  Transportation illumination - - railroad, commercial aviation, station, wharf, road and so on;
  Public lighting - - bank, hospital, school, gas station, sports facility and so on;
  Commercial illumination - - large or middle scale markets, shopping center, supermarket, guesthouse, hotel, large-scale billboard and so on;
  Factory illumination - - electric power, communication, spinning and weaving, papermaking, mechanical electron, petroleum chemical industry, clothing, food processing and soon..

·GGDZ series lighting energy saver

I. GGDZ series lighting energy saver structure and principle
GGDZ series lighting energy saver (refers to GGDZ LESC) is consist of compensation transformer, adjust transformer, voltage adjust actuating system, control circuit, time control circuit, protection circuit and so on.


GGDZ lighting energy saver system block diagram

    GGDZ LESC work principle: when load is connected to the supply output, sampling circuit react immediately to get the output voltage. The servo system is determined by the value of the (Vout-Vref). It drives the voltage adjust actuating system to move up and down on the top of the columnar adjust transformer. The compensation provides compensated voltage to return the Vout to its normal value.

II. GGDZ LESC technical Specifications

Input voltage range 

180V-260V

 

Wind temperature rise

80℃

Output voltage range 

190V-220V

Environment temperature

-20℃~+45℃ 

Frequency

50HZ

Insulation resistance

>2MΩ

Tolerance

≤±2 %

Hi-pot

2000V 1min

Output voltage wave shape  

Sine wave 

Connection mode

Serial connect


III. GGDZ LESC mode and type
     Single-phase serial mode table

NO.

Mode

Capacity
(KVA)

Rated current
(A)

Dimension
W×D×Hmm

Recommended cable
(mm2)

1

GGDZ-1005

5

23

320×500×800

2×2.5

2

GGDZ-1010

10

45

2×6

3

GGDZ-1015

15

68

2×16

4

GGDZ-1020

20

91

2×25

5

GGDZ-1030

30

136

500×600×1100

2×35

6

GGDZ-1040

40

182

2×50

7

GGDZ-1050

50

227

2×70

8

GGDZ-1060

60

272

2×95

     Three-phase serial mode table

NO.

Mode

Capacity
(KVA)

Rated current
(A)

Dimension
W×D×Hmm

Recommended cable
(mm2)

1

GGDZ-3010

10

15

600×420×1150

4×2.5

2

GGDZ-3020

20

30

4×6

3

GGDZ-3030

30

46

4×10

4

GGDZ-3050

50

76

850×620×1400

4×25

5

GGDZ-3075

75

114

4×50

6

GGDZ-3100

100

152

4×70

7

GGDZ-3150

150

228

1050×850×1800

4×120

8

GGDZ-3180

180

273

4×150

9

GGDZ-3225

225

342

2×(4×95)

10

GGDZ-3250

250

380

1200×1000×2000

2×(4×95)

11

GGDZ-3300

300

456

2×(4×120)

12

GGDZ-3350

350

532

2×(4×150)

13

GGDZ-3400

400

608

2×(4×185)

14

GGDZ-3450

450

684

1500×1100×2200
(double)

bar copper

15

GGDZ-3500

500

760

16

GGDZ-3550

550

836

17

GGDZ-3600

600

912


IV. GGDZ LESC installation and debug

Basis dimension diagram(mm)
    If it is set outdoor, concrete basis is needed. Calculate holes position according to “Basis dimension diagram”. 4 pieces of 10mm screws are required to be planted with 50mm outside basis top.

1.Open packing and inspection

  (1)Whether the cabinet is received in good condition or not
  (2)Whether the accessories are well-appointed or not
  (3)Whether the compensation transformer, adjust transformer and other parts whether they are received in good condition or not
  (4)Whether the fix parts are loosen, moved and connection between each terminal are well connected or not
  (5)Whether the voltage adjust system, actual system are reliable or not. If the carbon brush is broken, it should be replaced.
Note: When the equipment is received, make sure don’t put it in wet environment for long time.

2.Installation notice
  (1) Handle with care, extremely incline is forbidden. The equipment should be placed on flat basic.
  (2) There should be enough space where it is set to provide good air circulation

3.Insulation
  (1)Short circuit “input terminal” and “output terminal”, to get a test point.
  (2)Test the insulation resistance from the test point to ground with DC 1000 megohm, the value must be larger than 2MΩ.

4.Wiring check
  (1) Check the main circuit. If wiring to circuit contactor becomes flexible, screw down it.
  (2) Check every parts on the panel back face, such as current meter, indicator button, switch, if connection point becomes flexible, screw down..
  (3) Check control PCB, if wiring to it becomes flexible, screw down
  (4).Check servo mechanism on the adjust transformer, if limit switch becomes flexible, screw down.

5.Install and wire
  (1) 100KVA under savor cabinet: Lead three input lines through back bottom of the cabinet, to three terminals marked input “A,B,C”.
  (2) 100KVA under savor cabinet: Lead three input lines to three top terminals of air switch .
  (3) Cabinet protection earthed: earth wire should be connected to terminal marked “earth”. Earth wire resistance should be smaller than 4Ω

V. GGDZ LESC set and operation
  (I) Chief operation
1. Manual switch on
    Turn SB3 to “Manual switch on”, SB4 to “Energy save mode”, set time control unit KT3 to “open” (screen displays “ON”)

LESC panel diagram
    Move city power to LESC, switch on air switch Q1, press start button SB1 10 seconds later. Then output circuit contact KM1 closed, LESC supply output. Indicators A, B and C on panel are light, and “Energy save mode” indicator is light too.

2.Time control start
    Turn SB3 on panel to “switch on Automatically”, SB4 to “Energy save mode”, set time control unit KT3 start time.
    Move city power to LESC, switch on air switch Q1, press start button SB1 10 seconds later. Then output circuit contact KM1 closed, LESC supply output. Indicators A, B and C on panel are light, and “Energy save mode” indicator is light too.

3.Stop equipment
    When LESC is using, press stop button SB2 on panel, circuit contact open, LESC cut off

4.Manual by-pass
    When LESC is in working state or stop state (time control unit KT3 is “ON”), press SB4 on panel to “By-pass”, then city power will go through to load by-pass.

5.Protection circuit
(1)Over-voltage and under-voltage protection
    If one phase happens to over-voltage or under-voltage, circuit contact KM1 open ,circuit contact KM2 close, then city power go directly to load through by-pass. Protection indicator and by-pass indicator turn on. “Energy save” indicator turn off.
(2) Over load and short circuit protection
    When over loaded, over load protection relay works, circuit contact KM1 opens, circuit contact KM2 closes, city power go through by-pass to load.
    Short circuit function is executed by air switch Q1.

(II)Time controller operation and setting
    After installation, turn “Automatic switch on/manual switch on” switch to “manual switch on”. Move input power to LESC, switch on the air switch in cabinet.
Latitude time controller controls the on or off the output voltage. Time controller KT1 associate with KT2 controls each detail time of step voltage. The fallowing table shows every voltage step and indicators state.

Output step voltage

KT1indicator
ON 1

KT2 indicator
ON 2

KT3 indicator
ON

Output voltage

No output

 

 

 

0V

Rated voltage output

 

 

ON

220V

First voltage step

ON

 

ON

210V(default value)

Second voltage step

ON

ON

ON

195V(default value)

Time controller operation manual ( Note: Latitude time controller KT3 is different with KT1 and KT2 )

    First time to use, or after a long time no use, if there’s no display on LCD, please electrify it for 5 minutes, then press reset
button to start.
  1、KT3(Latitude time controller)
  setting pre-work.
  (1)Find out latitudes in location,
accuracy is one degree.
  (2)Confirm the on/off time of load.
  (3)Confirm date

  Note
  (1)KT3 is 24 hour mode
  (2)6 on/off control time could be set.


Latitude time controller KT3 panel picture

procedure

Setting item

Button

Display

Remark

Way to enter

1

Latitude set

press>button set North globe ﹨South globe

n twinkles

N north globe
S South globe

Press p 可simultaneously to set latitude

press^ button to change N-S

 

press>button to set latitude

01
twinkles

number increased, pressing ^ button and hole

press^ button to change latitude

 

2

Set date

Press P to set date

01 01

 

 

Press p 可simultaneously to set date

Press > to set month

Month twinkles

number increased, pressing ^ button and hole

Press ^button to change month

 

Press >button to set date

Date twinkles

number increased, pressing ^ button and hole

press^ button to change date

 

3

Set on/off time

Press P to enter

 

Set first on time

Press P to enter

Press>set time

 

If latitude function is no need, press
button to make
icon disappear. Then automatic time adjust by latitude will cancelled

Press^ button to change

 

Press >set minute

 

Press P to enter

 

Set first off time

Press^ button to change

 

Press> to set minute

 

Repeat the above procedure to set 2-6 on/off time.

 

 

4

Set current time

press > buttons,to set current time

Hour twinkles

number increased, pressing ^ button and hole


press > buttons

press^ to change

 

 

Re-press > buttons to set minute

Minute twinkles

 

5

Set the working status

Press MANUAL to set current work status.
If set 19:00 on,7:00 off current time is 10:00, it is suppose to set AT OFF;
If current time is 22:00,it is suppose to set ON AT

ON AT : Automatic on/off state, it is on now
ON: Always on
OF: Always off
AT OFF: Automatic on/off state, it is off now

Check:Press(P)button to check if time setting is correct.
Manual control:Press(MANUAL)button, realize the intended on/off
If it is vacant in 30 seconds, time controller will return to time display, then enter to set according to procedures referred in the above table.

2.KT1、KT2 setting
    KT1 and KT2 is 24 hour mode. If 12 hour mode is needed, press “Clock” button and hold for 5 seconds, it displays AM in top left corner. It indicates 12 hour mode. Re-press 5 seconds, it returns to 24 hour mode, AM icon disappeared. (When in 12 hour mode, AM indicates a.m., PM indicates p.m.)

Time controller KT1、KT2 panel

(1)Set first step voltage and second step voltage on/off time
.
Setting points
  KT1 is used to set “first step voltage” on/off time.
  KT2is used to set “second step voltage” on/off time.
  If turn “first step voltage” to “second step voltage”, KT1 is supposed to set“ON”.
  If turn “second step voltage” to “first step voltage”, KT1 and KT2 is supposed to set “OFF”.
  If rated output voltage is required, both KT1 and KT2 are supposed to set “OFF”.
  KT1 and KT2 can set 4 groups on/off time.

Procedure

Button

Setting item

1

press(set)

setfirst step voltage“1-4 on/off time(displays 1 ON)

2

press(week)

set“every day same”,or“Monday~Friday”,“Saturday~Sunday”,or“Differ in every day”(don’t press this button, if every day is the same,then week is not displayed;meanwhile, don’t press this button when adjust clock)

3

press(hour)(minute)

Set first on time

4

press(set)

Set off time(displays 1 OFF)

5

press(week)

don’t press this button if every off date is the same

6

press(hour)(minute)

Set first off time

7

Repeat procedure 2-6

set“first step voltage”2-4 on/off time
(If no need, press set key to overleap)

8

Press (set)

set“second step voltage”1-4 on/off time
Note:“second step voltage”on time set,after“first step voltage”the 4th off time set. Set procedure is same to “first step voltage”

9

press(hour)

complete time set

* If less than 8 on/off time is needed, press (hour) button to adjust clock.
* If wrong set, or to cancel set, press (manual control 1) or (manual control 2) button; Re-press them, primary set resumes.
* Displays (--∶--)when not set

(2)Clock adjust
·Press and hold (clock), then press (week) time after time to current date. (If everyday on/off time is the same, instead of pressing this button, directly adjust hour and minute.)

MO

TU

WE

TH

FR

SA

SU

Monday

Tuesday

Wednesday

Thursday

Friday

Saturday

Sunday

·Press (Clock) and hold, then press (hour) or (minute) to adjust time.

(3)Set time controller work status
    Press (manual control 1) or (manual control 2) button, LCD displays ON AT (Automatic on) of AT OFF (Automatic OFF)

display

indicates

ON AT

Time controller is on automatic control status, and is being on state.

AT OFF

Time controller is on automatic control status, and is being off state.

ON

Time controller is being on state, but it can’t be on/off according to set time.

OFF

Time controller is being off state, on/off time set is invalid.

Note: Displays 1 indicates in “first step voltage” control status
      Displays 2 indicates in “second step voltage” control status

(4)Check: press (set) button, check if set time is right or not.
(5)Modify: press (manual control 1) or (manual control 2) button, then reset on/off time.
(6)Complete check: press (Clock ) button, to complete check and set.
(7)Manual control: press (manual control 1) or (manual control 2) button, related step voltage could be turn on or off.

Note: ·On/off time set should be set in order. It’s can’t be set in cross order.
      ·To control according to set time, time controller status is supposed to set on automatic mode. Viz. ON AT or At OFF.
      ·Reset button will clean all set data, please don’t use it at will.

3.Idle test
After finishing setting time control unit, start LESC idle by manual (refer to manual switch on), test LESC idle. Then test “manual by-pass” function.

4.Load test
After finishing setting time control unit and idle test, remove city power from LECS, connect load to supply output, then start LESC by manual. At this moment, current meter displays each phase. Their value should within rated current.
Observe for 20 minutes, then check whether there’s any smell from transformer. It’s temperature rise supposed to <80℃. Observe other limit performance and adjust system action. If there’s no abnormality, it means LESC works normally.

5.Notice
(1) No chemistry precipitate and dirt, no harmful corrosive medium and the flammable explosive gas where LESC is put.
(2)Over-load use for long time is not permitted.
(3)When used normally, if the air switch tripped, it means over-load or short circuit. Malfunction should be fixed before re-switch on air switch. Otherwise, LESC will be awfully damaged.
(4) If abnormal smell and smoke is found, switch off the city power immediately, then send specialist for repair
(5)Users are recommended to install an air switch to input power to LESC. It will be advantageous for maintenance.
(6)LESC must be wired with neutral line.

VI.GGDZ LESC daily maintenance

    Check LESC in fix time. Measure transformer temperature rise whether they are normal or not. Whether load exceeds dated range. Whether voltage adjust system is normal or not. Whether carbon brushes become flexible or not. Whether they are on same level and they are well contacted. Any abnormality is not permitted. Once found, it should be fixed in time. If there’s still any question, please don’t be hesitated to get in touch with manufacture.
Monthly maintenance is recommended. Maintenance item:
  1.Clean dusty inside cabinet。
  2.Check electrical parts whether there’s damaged or not. If there’s damaged, replace it in time.
  3.Whether voltage adjust system works normally. Replace awfully worn carbon brushes. Dry adjust   transformer coil with tetreoxide and cotton. If there’s any burnt point, polish it with size 0 sand paper in time.
  4.Make detail maintenance recorder.

Malfunctions and exclusions

NO.

Malfunctions

causes

Fixed methods

1

Can’t start

①Input voltage is out of range or city power is abnormal
②Air switch inside cabinet isn’t switched on or damaged.

①Check city power wiring whether they are normal or not.
②Switch on it or replace

2

Can’t adjust voltage

①Sampling transformer is damaged
②Control PCB is damaged
③Electrical motor is damaged

Repair or replace

3

Adjust voltage in one direction

①Limit switch normal close contact is damaged
②Relay K1 or K2 is damaged.

Replace

4

No supply output voltage

①Stop button SB2 normal close contact is open
②Circuit contact KM1 in main circuit is damaged.

Replace

5

Air switch trips usually

Protection circuit occurs to malfunction.

Send specialists for repair

Accessory list:one product manual and one unit of circuit diagram.